Market entry rules · Germany · medical devices and diagnostics

Twelve things that sit between a device maker and a German hospital, in order.

A German hospital, buying group or dealer can take a device from a Greek or Cypriot maker once the CE file, the EUDAMED entries, the German labels and the buying route are settled. Dates and routes change, so confirm each regulatory one with the authority or the notified body before you ship.

  1. CE marking: the Medical Device Regulation (MDR) 2017/745 sorts devices into classes I, IIa, IIb and III. A plain class I device is self-declared. Sterile, measuring and reusable surgical class I devices and all higher classes need a notified body, whose number follows the CE mark (Articles 20 and 52). The IVD Regulation 2017/746 uses classes A to D, and only a non-sterile class A is self-declared (Article 48).source
  2. Deadlines: a device on a directive certificate may stay on sale to 31 December 2027 (class III, most implantable IIb) or 2028 (others). The maker must have applied to a notified body by 26 May 2024 and signed with it by 26 September 2024 (Regulation 2023/607). IVDs: certificate holders to 2027, self-declared devices needing a notified body to 2027 (D), 2028 (C) or 2029 (B, sterile A) (Regulation 2024/1860).source
  3. EUDAMED: since 28 May 2026 four modules are mandatory: actors, UDI and devices, notified bodies and certificates, market surveillance. The maker registers as an actor first, then each new device with its Basic UDI-DI before the first sale, and older devices by 28 November 2026. Distributors do not register (Commission Q&A). The UDI barcode goes on the label and each higher pack level (MDR Article 27).source
  4. MPDG: the German implementing law adds no national registration for standard devices. Since 28 May 2026 devices are registered in EUDAMED and no longer in the BfArM portal DMIDS. Incident reports for Germany go to BfArM or the Paul-Ehrlich-Institut. A representative who briefs clinicians on a device needs the expertise section 83 describes (Medizinprodukteberater).source
  5. Dealer checks: Article 14 has the dealer check the CE mark, declaration of conformity, labels, instructions and UDI. For Greek and Cypriot goods the dealer is a distributor, not an importer (Article 2). One German dealer's quality agreement asks a supplier with a certified quality system to show its ISO 13485 or 9001 certificate, update certificates within 8 weeks and keep batch traceability (confirm per buyer).source
  6. Purchasing group: Prospitalia is one German hospital buying group, with over 1,300 member facilities. A maker asks to become a supplier through its callback form. It offers suppliers a check of product master data against COVIN, the rules written by German purchasing groups, and eCl@ss classification. Its EU tenders for members end in framework contracts without a purchase obligation (tender page).source
  7. Public tender: from 216,000 euros without VAT, a public hospital must tender supplies. That is the sub-central threshold for 2026 and 2027 (Delegated Regulation 2025/2152), and German law applies the EU figure (section 106 GWB). Below it national rules apply. A hospital counts as a public buyer only under the tests in section 99 GWB, so ask each one. A purchasing group may tender for its members.source
  8. Reimbursement: three routes by product. Aids sold through a Sanitätshaus need a Hilfsmittelverzeichnis listing, applied for at the GKV-Spitzenverband (section 139 SGB V). Hospital products are paid in DRG case fees, and the hospital asks InEK by 31 October about extra payment for a new method (section 6 KHEntgG). Health apps of class I, IIa or IIb go into the DiGA directory at BfArM (sections 33a and 139e).source
  9. German language: the MDR leaves the language to each state (Article 10(11)). MPDG section 8 requires user, patient and implant information in German and allows the declaration of conformity in German or English. English can serve professional users if the safety information is also in German or their language. A dealer that relabels needs a certified quality system (MDR Article 16).source
  10. Packaging: since 12 August 2026 the EU Packaging Regulation and the VerpackDG replace the VerpackG. The first company in the German supply chain is the producer, and a foreign maker that delivers straight to a German end buyer is the producer itself. It registers in LUCID, licenses consumer packaging with a system operator and, with no German office, appoints an authorised representative.source
  11. ElektroG: it covers medical devices except active implants and those expected to turn infectious. The producer registers before sale, and a foreign producer without a German office appoints a representative (sections 6 and 8), or the duty falls on the German company that first offers the device. From 18 February 2027 portable batteries must be user-replaceable (Battery Regulation Article 11), with exceptions.source
  12. Payment: a term over 60 days is valid only if agreed expressly and not grossly unfair (section 271a BGB). For a public hospital, a term over 30 days needs an express agreement and an objective reason, and over 60 days it is void. An inspection period over 30 days is limited the same way. The statute sets limits, not the hospital's real pace, so agree the term in writing.source